AND 0 run-time group
AND 0 input I0
p20030[0]
(0)
AND 0 input I1
p20030[1]
(0)
AND 0 input I2
p20030[2]
(0)
AND 0 input I3
p20030[3]
(0)
AND 1 run-time group
AND 1 input I0
p20034[0]
(0)
AND 1 input I1
p20034[1]
(0)
AND 1input I2
p20034[2]
(0)
AND 1 input I3
p20034[3]
(0)
1
2
DO: All Objects
FBLOCKS - AND (AND function block with 4 inputs)
Logic function blocks
AND 0
p20032 (9999)
I0
I1
AND 0 output Q
Q
r20031
I2
I3
AND 0 run sequence
p20033 (10)
AND 1
p20036 (9999)
I0
I1
AND 1 output Q
Q
r20035
I2
I3
AND 1 run sequence
p20037 (20)
3
4
AND 2
AND 2 run-time group
p20040 (9999)
AND 2 input I0
p20038[0]
I0
(0)
AND 2 input I1
p20038[1]
I1
(0)
AND 2 input I2
p20038[2]
I2
(0)
AND 2 input I3
p20038[3]
I3
(0)
AND 2 run sequence
p20041 (30)
AND 3
AND 3 run-time group
p20044 (9999)
AND 3 input I0
p20042[0]
I0
(0)
AND 3 input I1
p20042[1]
I1
(0)
AND 3 input I2
p20042[2]
I2
(0)
AND 3 input I3
p20042[3]
I3
(0)
AND 3 run sequence
p20045 (40)
5
6
Function diagram
fp_7210_98_eng.vsd
SINAMICS S110
20.04.09 V04.04.00
AND 2 output Q
Q
r20039
AND 3 output Q
Q
r20043