Siemens SINAMICS S110 List Manual page 64

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
23
Current measurement oversampling avail-
able
24
Keep the relevant data for parking available Yes
25
Internal fan operating hours counter avail-
able
26
Software gating unit in the CU is supported
27
Current controller dynamics higher
Notice:
This information represents the characteristics/features of the power unit firmware. It does not provide informa-
tion/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware sup-
ports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note:
Re bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage protec-
tion (p1231 = 3).
Re bit 10:
The Motor Module supports the autonomous internal voltage protection. If the voltage protection function is inter-
nally activated (p1231 = 3) the Motor Module decides autonomously - using the DC link voltage - as to whether the
short-circuit is activated.
Re bit 23:
The component supports the detection of current actual values (and the detection of valve close durations) with
double clocking and phase shift.
r0196[0...255]
DRIVE-CLiQ component status / DLQ comp status
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the status of DRIVE-CLiQ components.
r0196[0...1]: Not used
r0196[2]: Status of DRIVE-CLiQ component with component number 2
...
r0196[255]: Status of DRIVE-CLiQ component with component number 255
Note:
Structure of status value: Bits 31 ... 08, 07, 06 ... 04, 03 ... 00
Re Bit 31 ... 08: Reserved
Re Bit 07: 1: Part of target topology, 0: Only in actual topology
Re Bit 06 ... 04: 1: Active, 0: Inactive or parked
Re bit 03 ... 00:
0: Component data not available.
1: Power-up, acyclic DRIVE-CLiQ communication (LED = orange).
2: Ready for operation, cyclic DRIVE-CLiQ communication (LED = green).
3: Alarm (LED = green).
4: Fault (LED = red).
5: Detection via LED and ready for operation (LED = green/orange).
6: Detection via LED and alarm (LED = green/orange).
7: Detection via LED and fault (LED = red/orange).
8: Downloading firmware (LED = green/red at 0.5 Hz).
9: Firmware downloading completed, Waiting for POWER ON (LED = green/red at 2.0 Hz).
1-64
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents