Parameter
List of parameters
Note:
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
p1525[0...n]
CO: Torque limit lower/regenerative scaling / M_max low/gen scal
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
-2000.0 [%]
Description:
Sets the scaling for the lower torque limit or the torque limit when regenerating.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
r1526
CO: Torque limit upper/motoring without offset / M_max up w/o offs
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the upper torque limit of all torque limits without offset.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
r1527
CO: Torque limit lower/regenerative without offset / M_max low w/o offs
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the lower torque limit of all torque limits without offset.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
p1528[0...n]
CI: Torque limit upper/motoring scaling / M_max up/mot scal
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the upper or motoring torque limit in p1522.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
1-254
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: PERCENT
Max
2000.0 [%]
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 5620, 5630
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 3
Func. diagram: 5620, 5630
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 5620, 5630
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 1610, 3617,
5620, 5630
Unit selection: -
Expert list: 1
Factory setting
1524[0]