Siemens SINAMICS S110 List Manual page 354

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Dependency:
Refer to: p2292
p2299[0...n]
CI: Technology controller limit offset / Tech_ctrl lim offs
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Sets the signal source for the offset of the output limiting of the technology controller.
p2306
Technology controller fault signal inversion / Tec_ctrl fault inv
SERVO_S110-CAN
Can be changed: T
(Tech_ctrl),
Data type: Integer16
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0
Description:
Setting to invert the fault signal of the technology controller.
The setting depends on the type of control loop.
Value:
0:
1:
Caution:
If the actual value inversion is incorrectly selected, then the closed-loop control with the technology controller can
become unstable and can oscillate!
Note:
The correct setting can be determined as follows:
- inhibit the technology controller (p2200 = 0).
- increase the motor speed and in so doing, measure the actual value signal (of the technology controller).
- if the actual value increases with increasing motor speed, then the inversion should be switched out.
- if the actual value decreases with increasing motor speed, then the inversion should be set.
If value = 0:
The drive reduces the output speed when the actual value rises (e.g. for heating fans, intake pump, compressor).
If value = 1:
The drive increases the output speed when the actual value increases (e.g. for cooling fans, discharge pumps).
r2349.0...11
CO/BO: Technology controller status word / Tec_ctrl status
SERVO_S110-CAN
Can be changed: -
(Tech_ctrl),
Data type: Unsigned32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Displays the status word of the technology controller.
Bit field:
Bit
Signal name
00
Technology controller de-activated
01
Technology controller limited
02
Technology controller, motorized potentiom-
eter limited max.
03
Technology controller, motorized potentiom-
eter limited min.
1-354
No inversion
Inversion
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-