111:
999:
Dependency:
Refer to: p2038
Refer to: F01505, F01506
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are inhib-
ited.
The inhibited interconnections can only be changed again after setting value 999.
p0922
IF1 PROFIdrive telegram selection / IF1 PD Telegr_sel
SERVO_S110-DP
Can be changed: C2(1), T
(Pos ctrl),
Data type: Unsigned16
SERVO_S110-PN
(Pos ctrl)
P-Group: Communications
Not for motor type: -
Min
999
Description:
Sets the send and receive telegram.
Value:
999:
Dependency:
Refer to: p2038
Refer to: F01505, F01506
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are inhib-
ited.
The inhibited interconnections can only be changed again after setting value 999.
r0924[0...1]
ZSW bit pulses enabled / ZSW pulse enab
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the position of the "Pulses enabled" status signal in the PROFIdrive telegram.
Index:
[0] = Signal number
[1] = Bit position
p0925
PROFIdrive clock synchronous sign-of-life tolerance / PD SoL_tol
CU_S110-DP,
Can be changed: U, T
CU_S110-PN,
Data type: Unsigned16
SERVO_S110-DP,
P-Group: Communications
SERVO_S110-PN
Not for motor type: -
Min
0
Description:
Sets the number of tolerated consecutive sign-of-life errors of the clock-cycle synchronous master.
The sign-of-life signal is normally received in PZD4 (control word 2) from the master.
Dependency:
Refer to: p2045, r2065
Refer to: F01912
Note:
The sign-of-life monitoring is disabled for p0925 = 65535.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
SIEMENS telegram 111, PZD-12/12
Free telegram configuration with BICO
Free telegram configuration with BICO
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
999
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Parameter
List of parameters
Access level: 1
Func. diagram: 1520, 2420,
2422, 2423, 2424
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 3
Func. diagram: 2454, 2456
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2410
Unit selection: -
Expert list: 1
Factory setting
1
1-177