r1114
CO: Setpoint after the direction limiting / Setp after limit
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
(Extended set),
P-Group: Setpoints
SERVO_S110-PN
Not for motor type: -
(Extended set)
Min
- [rpm]
Description:
Displays the speed/velocity setpoint after the changeover and limiting the direction.
p1115
Ramp-function generator selection / RFG selection
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Integer16
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
0
Description:
Sets the ramp-function generator type.
Value:
0:
1:
Note:
Another ramp-function generator type can only be selected when the motor is at a standstill.
r1119
CO: Ramp-function generator setpoint at the input / RFG setp at inp
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
(Extended set),
P-Group: Setpoints
SERVO_S110-PN
Not for motor type: -
(Extended set)
Min
- [rpm]
Description:
Displays the setpoint at the input of the ramp-function generator.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The setpoint is influenced by other functions, e.g. skip (suppressed) speeds, minimum and maximum limits.
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
SERVO_S110-CAN
Can be changed: C2(1), U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
0.000 [s]
Description:
The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to the maximum speed
(p1082) in this time.
Dependency:
Refer to: p1082
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Basic ramp-function generator
Extended ramp-function generator
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
999999.000 [s]
Parameter
List of parameters
Access level: 3
Func. diagram: 1550, 3040,
3050
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 1550, 3080
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 1550, 1690,
3050, 3060, 3070
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 1
Func. diagram: 3060, 3070
Unit selection: -
Expert list: 1
Factory setting
10.000 [s]