Parameter
List of parameters
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
r1533
Current limit torque-generating total / Iq_max total
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [Arms]
Description:
Displays the maximum torque/force generating current as a result if all current limits.
r1534
CO: Torque limit upper total / M_max upper total
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the upper torque limit of all torque limits.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
r1535
CO: Torque limit lower total / M_max lower total
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the lower torque limit of all torque limits.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
r1538
CO: Upper effective torque limit / M_max upper eff
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the currently effective upper torque limit.
Note:
The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
1-256
Calculated: -
Dynamic index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 5640, 5722,
6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 1610, 5620,
5630, 5640
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 1610, 5620,
5630, 5640
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 2
Func. diagram: 1590, 1610,
5610, 5650
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]