Parameter
List of parameters
r0302[0...n]
Motor code number of motor with DRIVE-CLiQ / Motor code Mot DLQ
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
-
Description:
Displays the motor code number from the saved motor data from a motor with DRIVE-CLiQ.
Note:
Drive commissioning can only be exited if the code number that was downloaded (r0302) matches the stored code
number (p0301). If the numbers differ, then the motor data set should be re-loaded using p0300 = 10000.
The motor data are always expected from the first encoder that is assigned to the drive data sets (refer to p0187 =
encoder 1) data set number.
The value is not updated cyclically but only on specific events (e.g. update DRIVE-CLiQ device).
r0302 = 0: No motor with DRIVE-CLiQ found
r0303[0...n]
Motor with DRIVE-CLiQ status word / Motor w DLQ ZSW
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
-
Description:
Displays the status word of the automatic motor parameter sensing of a motor with DRIVE-CLiQ.
Motor parameter sensing takes place in the following events if the SMI is connected to the Motor Module and the
encoder is activated (p0145):
- Warm restart
- downloading projects.
- POWER ON (off/on).
- where p0300 = 10000, 10001.
Bit field:
Bit
Signal name
00
Motor data set selected
01
Motor connection type
02
Windings can be changed
03
Windings can be changed number
Dependency:
Refer to: p0145, p0300
Note:
SMI: SINAMICS Sensor Module Integrated
p0304[0...n]
Rated motor voltage / Mot U_rated
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0 [Vrms]
Description:
Sets the rated motor voltage (rating plate).
Dependency:
Refer to: p0349
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
When the parameter value is entered the connection type of the motor (star-delta) must be taken into account.
1-76
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
-
1 signal
MDS1
Delta
Yes
2
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
20000 [Vrms]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
MDS0
-
Star
-
No
-
0
-
Access level: 1
Func. diagram: 6300, 6724
Unit selection: -
Expert list: 1
Factory setting
0 [Vrms]