p2212[0...n]
CO: Technology controller, fixed value 12 / Tec_ctr fix val 12
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2213[0...n]
CO: Technology controller, fixed value 13 / Tec_ctr fix val 13
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2214[0...n]
CO: Technology controller, fixed value 14 / Tec_ctr fix val 14
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2215[0...n]
CO: Technology controller, fixed value 15 / Tec_ctr fix val 15
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-200.00 [%]
Description:
Sets the value for fixed value 15 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Parameter
List of parameters
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
120.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
130.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
140.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
150.00 [%]