Parameter
List of parameters
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fixed 13
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 13.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fixed 14
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 14.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1015[0...n]
CO: Fixed speed setpoint 15 / n_set_fixed 15
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 15.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1020[0...n]
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for selecting the fixed speed setpoint.
Dependency:
Selects the required fixed speed setpoint using p1020 ... p1023.
Displays the number of the actual fixed speed setpoint in r1197.
Sets the values for the fixed speed setpoints 1 ... 15 using p1001 ... p1015.
Refer to: p1021, p1022, p1023, r1197
Note:
If a fixed speed setpoint has not been selected (p1020 ... p1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
1-190
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 1021, 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 3
Func. diagram: 2505
Unit selection: -
Expert list: 1
Factory setting
0