Siemens SINAMICS S110 List Manual page 148

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Bit field:
Bit
Signal name
08
DI/DO 8 (X132.1)
09
DI/DO 9 (X132.2)
10
DI/DO 10 (X132.3)
11
DI/DO 11 (X132.4)
16
DO 16 (X131.5)
Notice:
Terminal DO 16 is used for Safety Extended Functions as soon as this is enabled using p9601 and assuming that it
is not controlled via PROFIsafe.
The signal source set in p0746 is then no longer output at terminal DO 16.
Note:
Inversion using p0748 has been taken into account.
DI/DO: Bidirectional Digital Input/Output
p0748
CU, invert digital outputs / CU DO inv
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Setting to invert the signals at the digital outputs.
Bit field:
Bit
Signal name
08
DI/DO 8 (X132.1)
09
DI/DO 9 (X132.2)
10
DI/DO 10 (X132.3)
11
DI/DO 11 (X132.4)
16
DO 16 (X131.5)
Notice:
If telegram 39x is set via p0922 in SINAMICS Integrated, the inversion of the output has no effect.
Note:
DI/DO: Bidirectional Digital Input/Output
r0752
CO: CU analog input, input voltage actual / CU AI U_input act
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Terminals
Not for motor type: -
Min
- [V]
Description:
Displays the actual input voltage at the analog input.
Note:
AI: Analog Input
p0753
CU analog input smoothing time constant / CU AI T_smooth
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Terminals
Not for motor type: -
Min
0.0 [ms]
Description:
Sets the smoothing time constant of the 1st-order low pass filter for the analog input.
Note:
AI: Analog Input
1-148
1 signal
High
High
High
High
High
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.0 [ms]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
0 signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
FP
Not inverted
2030
Not inverted
2030
Not inverted
2031
Not inverted
2031
Not inverted
2032
Access level: 1
Func. diagram: 2040
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 2040
Unit selection: -
Expert list: 1
Factory setting
0.0 [ms]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents