Siemens SINAMICS S110 List Manual page 40

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r0037[0...1]
Control Unit temperature / CU temperature
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the Control Unit temperature.
An appropriate message is output when 87 °C is exceeded.
Index:
[0] = Temperature actual
[1] = Temperature maximum
Dependency:
Refer to: A01009
Note:
The value of -200 indicates that there is no measuring signal.
r0037[0...19]
CO: Power unit temperatures / PU temperatures
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the temperatures in the power unit.
Index:
[0] = Inverter, maximum value
[1] = Depletion layer maximum value
[2] = Rectifier maximum value
[3] = Air intake
[4] = Interior of power unit
[5] = Inverter 1
[6] = Inverter 2
[7] = Inverter 3
[8] = Inverter 4
[9] = Inverter 5
[10] = Inverter 6
[11] = Rectifier 1
[12] = Rectifier 2
[13] = Depletion layer 1
[14] = Depletion layer 2
[15] = Depletion layer 3
[16] = Depletion layer 4
[17] = Depletion layer 5
[18] = Depletion layer 6
[19] = Cooling system liquid intake
Note:
The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
The maximum value is the temperature of the hottest inverter, depletion layer, or rectifier.
1-40
Calculated: -
Dynamic index: -
Units group: -
Scaling: p2006
Max
- [°C]
Calculated: -
Dynamic index: -
Units group: 21_1
Scaling: p2006
Max
- [°C]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: 8014
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]