Siemens SINAMICS S110 List Manual page 41

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p0045
Smoothing time constant, display values / T_smth display
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the smoothing time constant for the following display values:
SERVO: r0078[1], r0079[1], r0081 (calculated from the quantities smoothed with p0045), r0082[1].
VECTOR: r0063[1], r0068[1], r0080[1], r0082[1].
r0046.0...31
CO/BO: Missing enable sig / Missing enable sig
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays missing enable signals that are preventing the closed-loop drive control from being commissioned.
Bit field:
Bit
Signal name
00
OFF1 enable missing
01
OFF2 enable missing
02
OFF3 enable missing
03
Operation enable missing
04
Armature short-circuit / DC braking, enable
missing
05
STOP2 enable missing
06
STOP1 enable missing
08
EP terminals enable missing
09
Infeed enable missing
10
Ramp-function generator enable missing
11
Ramp-function generator start missing
12
Setpoint enable missing
16
OFF1 enable internal missing
17
OFF2 enable internal missing
18
OFF3 enable internal missing
19
Pulse enable internal missing
20
Armature short-circuit/DC braking internal
enable missing
21
STOP2 enable internal missing
22
STOP1 enable internal missing
25
Function bypass active
26
Drive inactive or not operational
27
De-magnetizing not completed
28
Brake open missing
29
Cooling system ready signal missing
30
Speed controller inhibited
31
Jog setpoint active
Dependency:
Refer to: r0002
Note:
The value r0046 = 0 indicates that all enable signals for this drive are present.
Bit 00 = 1 (enable signal missing), if:
- the signal source in p0840 is a 0 signal.
- there is a "switching on inhibited".
Bit 01 = 1 (enable signal missing), if:
- the signal source in p0844 or p0845 is a 0 signal.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameter
List of parameters
Access level: 2
Func. diagram: 4715, 5610,
5730, 6714, 8012
Unit selection: -
Expert list: 1
Factory setting
1.00 [ms]
Access level: 1
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
7014,
7016
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
7014,
7016
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
1-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents