Siemens SINAMICS S110 List Manual page 189

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fixed 12
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 12.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Parameter
List of parameters
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
1-189

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents