Siemens SINAMICS S110 List Manual page 65

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r0197
Bootloader vers / Bootloader vers
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Displays the bootloader version.
Dependency:
Refer to: r0018, r0128, r0148, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0198[0...1]
BIOS/EEPROM data version / BIOS/EEPROM vers
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version
Dependency:
Refer to: r0018, r0128, r0148, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0199[0...24]
Drive object name / DO name
SERVO_S110-CAN,
Can be changed: C1
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note:
The parameter is not influenced by setting the factory setting.
r0200[0...n]
Power unit code number actual / PU code no. act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
-
Description:
Displays the unique code number of the power unit.
Note:
r0200 = p0201: No power unit found
For parallel circuit configurations, the parameter index is assigned to a power unit.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: PDS
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-65

Hide quick links:

Advertisement

Table of Contents
loading