Siemens SINAMICS S110 List Manual page 725

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p20265
INT 0 run sequence / INT 0 RunSeq
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run sequence of instance INT 0 within the run-time group set in p20264.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20266
CI: LVM 0 input X / LVM 0 input X
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of input quantity X of instance LVM 0 of the double-sided limiter.
p20267
LVM 0 interval average value M / LVM 0 avg value M
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Setting parameter for the interval average M of instance LVM 0 of the double-sided limiter.
p20268
LVM 0 interval limit L / LVM 0 limit L
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Setting parameter for the interval limit L of instance LVM 0 of the double-sided limiter.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
32000
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Parameter
List of parameters
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
700
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0.0000
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0.0000
1-725