Siemens SINAMICS S110 List Manual page 969

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Acknowledging faults
The list of faults and alarms specifies how to acknowledge each fault after the
cause has been remedied.
Table 3-3
Acknowledging faults
Acknowledg-
ment
POWER ON
The fault is acknowledged by a POWER ON (switch drive unit off and on again).
Note:
If this action has not eliminated the fault cause, the fault is displayed again immediately
after power up.
IMMEDIATELY
Faults can be acknowledged on one drive object (Points 1 to 3) or on all drive objects
(Point 4) as follows:
1 Acknowledging by setting parameter:
p3981 = 0 --> 1
2 Acknowledging via binector inputs:
p2103
p2104
p2105
3 Acknowledging via a PROFIBUS control signal:
STW1.7 = 0 --> 1 (edge)
4 Acknowledge all faults
p2102
All of the faults on all of the drive objects of the drive system can be acknowledged
using this binector input.
Note:
• These faults can also be acknowledged by a POWER ON operation.
• If this action has not eliminated the fault cause, the fault will continue to be displayed
after acknowledgment.
• Safety Integrated faults
The "Safe standstill" (SH) function must be deselected before these faults are
acknowledged.
PULSE INHIBIT The fault can only be acknowledged with a pulse inhibit (r0899.11 = 0).
The same options are available for acknowledging as described under acknowledgment
with IMMEDIATELY.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description
BI: 1. Acknowledge faults
BI: 2. Acknowledge faults
BI: 3. Acknowledge faults
BI: Acknowledge all faults
Faults and alarms
Overview of faults and alarms
3-969

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents