Parameter
List of parameters
p0855[0...n]
BI: Unconditionally release holding brake / Uncond open brake
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for the command "unconditionally open holding brake".
Dependency:
Refer to: p0858
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The signal via BI: p0858 (unconditionally close holding brake) has a higher priority than via BI: p0855 (uncondition-
ally open holding brake).
p0856[0...n]
BI: Speed controller enable / n_ctrl enable
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for the command "enable speed controller" (r0898.12).
0 signal: Set the I component and speed controller output to zero.
1 signal: Enable speed controller.
Dependency:
Refer to: r0898
Note:
If "enable speed controller" is withdrawn, then an existing brake will be closed.
If "speed controller enable" is withdrawn, the pulses are not suppressed.
p0857
Power unit monitoring time / PU t_monit
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Commands
Not for motor type: -
Min
100.0 [ms]
Description:
Sets the monitoring time for the power unit.
The monitoring time is started after an 0/1 edge of the ON/OFF1 command. If the power unit does not return a
READY signal within the monitoring time, then fault F06000 (infeeds) or F07802 (drives) is output.
Dependency:
Refer to: F07802, F30027
Notice:
The maximum time to pre-charge the DC link is monitored in the power unit and cannot be changed. The maximum
duration of the pre-charging depends on the power class and the power unit design.
The monitoring time for the pre-charging is started after the ON command (BI: p0840 = 0/1 signal). Fault F30027 is
output when the maximum pre-charging duration is exceeded.
Note:
The factory setting for p0857 depends on the power class and the design of the power unit.
The monitoring time for the ready signal of the power unit includes the time to pre-charge the DC link and, if rele-
vant, the de-bounce time of the contactors.
If an excessively low value is entered into p0857, then after enable, this results in the corresponding fault.
1-170
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
60000.0 [ms]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 2501, 2701,
2707
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2501, 2701,
2707
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 8760, 8864,
8964
Unit selection: -
Expert list: 1
Factory setting
6000.0 [ms]