r1539
CO: Lower effective torque limit / M_max lower eff
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the currently effective lower torque limit.
Note:
The effective lower torque limit is reduced with respect to the selected lower torque limit p1521, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
p1542[0...n]
CI: Travel to fixed stop torque reduction / TfS M_red
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Sets the signal source for the torque/force reduction when traversing to a fixed stop. This value is converted into a
factor and is interconnected to the scaling of the torque/force limits.
Dependency:
Refer to: p1528, p1529, r1543, p1544, p1545
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
r1543
CO: Travel to fixed stop torque scaling / TfS M scal
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
- [%]
Description:
Displays the internally converted factor to interconnect to the scaling of the torque/force limits.
Dependency:
Refer to: p1528, p1529, p1542, p1544, p1545
p1544
Travel to fixed stop evaluation torque reduction / TfS M_red eval
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: -
Min
0 [%]
Description:
Sets the evaluation for the torque/force reduction when traversing to a fixed stop.
Dependency:
Refer to: p1528, p1529, p1542, r1543, p1545
Note:
4000 hex (16384 dec) in the MOMRED control word corresponds to a reduction by the percentage specified in this
parameter.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535 [%]
Parameter
List of parameters
Access level: 2
Func. diagram: 1590, 1610,
5610, 5650
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 5610
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 5610
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 5610
Unit selection: -
Expert list: 1
Factory setting
100 [%]
1-257

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents