Siemens SINAMICS S110 List Manual page 95

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r0395[0...n]
Actual stator resistance / R_stator act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
- [ohm]
Description:
Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency:
In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note:
In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
r0396[0...n]
Actual rotor resistance / R_rotor act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL, FEM
Min
- [ohm]
Description:
Displays the actual rotor/secondary section resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency:
Refer to: p0354, p0620
Note:
In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
p0400[0...n]
Encoder type selection / Enc_typ sel
SERVO_S110-CAN,
Can be changed: C2(1, 4)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
202:
204:
242:
244:
1001: Resolver 1 speed
1002: Resolver 2 speed
1003: Resolver 3 speed
1004: Resolver 4 speed
2001: 2048, 1 Vpp, A/B C/D R
2002: 2048, 1 Vpp, A/B R
2003: 256, 1 Vpp, A/B R
2004: 400, 1 Vpp, A/B R
2005: 512, 1 Vpp, A/B R
2006: 192, 1 Vpp, A/B R
2007: 480, 1 Vpp, A/B R
2008: 800, 1 Vpp, A/B R
2010: 18000, 1 Vpp, A/B R distance-coded
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No encoder
DRIVE-CLiQ encoder AS20, singleturn
DRIVE-CLiQ encoder AM20, multiturn 4096
DRIVE-CLiQ encoder AS24, singleturn
DRIVE-CLiQ encoder AM24, multiturn 4096
Calculated: -
Dynamic index: MDS, p0130
Units group: 16_1
Scaling: -
Max
- [ohm]
Calculated: -
Dynamic index: MDS, p0130
Units group: 16_1
Scaling: -
Max
- [ohm]
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
10100
Parameter
List of parameters
Access level: 3
Func. diagram: 6300, 6730,
6731, 6732
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
Access level: 3
Func. diagram: 6730
Unit selection: p0349
Expert list: 1
Factory setting
- [ohm]
Access level: 1
Func. diagram: 1580, 4704
Unit selection: -
Expert list: 1
Factory setting
0
1-95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents