If a valid bearing type (p0530) is entered, the parameters in the bearing list cannot be changed (write protection).
Write protection is canceled if bearing type 1 is entered.
Notice:
If p0530 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also asso-
ciated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the motor
(p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note:
For a motor with DRIVE-CLiQ, p0530 can only be changed to the value 1 (manual entry).
p0531[0...n]
Bearing code number selection / Bear. code num sel
SERVO_S110-CAN,
Can be changed: C2(3)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: FEM
Min
0
Description:
Display and setting the bearing code number.
It is pre-assigned automatically (from the parameter lists which are available internally) when p0301 and p0530 are
entered and cannot be changed (write protection). The information in p0530 should be observed when removing
write protection.
When changing the bearing code number (except in the case of changing the value to 0), all of the bearing param-
eters are pre-assigned from the parameter lists which are available internally.
Dependency:
Refer to: p0301, p0530, p1082
Notice:
If p0531 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also asso-
ciated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the motor
(p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note:
p0531 cannot be changed on a motor with DRIVE-CLiQ.
p0532[0...n]
Bearing maximum speed / Bearing n_max
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: FEM
Min
0.0 [rpm]
Description:
Sets the maximum speed for the bearing.
Dependency:
Refer to: p1082
Caution:
This parameter is pre-assigned in the case of motors from the motor list (p0301) if a bearing type (p0530) or a bear-
ing code (p0531) is selected. When selecting a catalog motor, this parameter cannot be changed (write protection).
The information in p0530 should be observed when removing write protection.
Notice:
If p0532 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also asso-
ciated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the motor
(p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
p0570
Inhibit list values effective number / Inhib list no
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Applications
Not for motor type: -
Min
0
Description:
Sets the number of parameters in the inhibit list p0571 that should be withdrawn from the automatic motor and
closed-loop control parameter calculation (refer to p0340, p0578), starting from index 0.
Note:
Defines the number of entries in p0571 that should be taken into account. This means that a value of 0 de-activates
the complete list.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
210000.0 [rpm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
50
Parameter
List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.0 [rpm]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-129