Siemens SINAMICS S110 List Manual page 224

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r1229.1...11
CO/BO: Motor holding brake status word / Brake ZSW
SERVO_S110-CAN
Can be changed: -
(Extended brk),
Data type: Unsigned32
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Displays the status word for the motor holding brake.
Bit field:
Bit
Signal name
01
Command open brake (continuous signal)
03
Pulse enable, extended brake control
04
Brake does not open
05
Brake does not close
06
Brake threshold exceeded
07
Brake threshold undershot
08
Brake monitoring time expired
09
Pulse enable request missing/n_ctrl inhib-
ited
10
Brake OR logic operation result
11
Brake AND logic operation result
p1230[0...n]
BI: Armature short-circuit / DC braking activation / ASC/DCBRK act
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal source to activate the armature short-circuit or DC braking.
Dependency:
Refer to: p1231, p1232, p1233, p1234, p1235, p1236, p1237, r1238, r1239, p1345, p1346
Note:
1 signal: Armature short-circuit/DC braking activated.
0 signal: Armature short-circuit/DC braking de-activated.
p1231[0...n]
Armature short-circuit / DC braking configuration / ASC/DCBRK config
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
0
Description:
Setting to activate the various types for armature short-circuit / DC braking.
Value:
0:
1:
2:
4:
5:
14:
Dependency:
Refer to: p0300, p1230, p1232, p1233, p1234, p1235, p1236, p1237, r1238, r1239, p1345, p1346
Danger:
Re p1231 = 1, 2:
- only short-circuit-proof motors may be used, or suitable resistors must be used to short-circuit the motor
1-224
No function
External armature short-circuit with contactor feedback signal
Ext. armature short circuit without contactor feedback signal
DC braking
DC braking for OFF1/OFF3
DC braking below starting speed
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
14
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
2711
No
2711
No
2711
No
2711
No
2707
No
2704
No
2704
No
2707
No
2707
No
2707
Access level: 1
Func. diagram: 7014, 7016,
7017
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7014, 7016,
7017
Unit selection: -
Expert list: 1
Factory setting
0

Hide quick links:

Advertisement

Table of Contents