Siemens SINAMICS S110 List Manual page 199

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p1071[0...n]
CI: Main setpoint scaling / Main setp scal
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for scaling the main setpoint.
r1073
CO: Main setpoint effective / Main setpoint eff
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
- [rpm]
Description:
Displays the effective main setpoint. The value shown is the main setpoint after scaling.
p1075[0...n]
CI: Suppl setpoint / Suppl setpoint
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for the supplementary setpoint.
Dependency:
Refer to: p1076, r1077, r1078
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for scaling the supplementary setpoint.
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
- [rpm]
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Parameter
List of parameters
Access level: 3
Func. diagram: 1550, 3030
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 3030
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 1550, 3030
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 1550, 3030
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 3030
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
1-199

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents