Siemens SINAMICS S110 List Manual page 348

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r2262
CO: Technology controller setpoint after filter / Tec_ctr set aftFlt
SERVO_S110-CAN
Can be changed: -
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
- [%]
Description:
Displays the smoothed setpoint after the setpoint filter (PT1) of the technology controller.
p2263
Technology controller type / Tec_ctrl type
SERVO_S110-CAN
Can be changed: T
(Tech_ctrl),
Data type: Integer16
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0
Description:
Sets the technology controller type.
Value:
0:
1:
p2264[0...n]
CI: Technology controller actual value / Tec_ctrl act val
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
-
Description:
Sets the signal source for the actual value of the technology controller.
p2265
Technology controller actual value filter time constant / Tec_ctrl act T
SERVO_S110-CAN
Can be changed: U, T
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
0.000 [s]
Description:
Sets the time constant for the actual value filter (PT1) of the technology controller.
r2266
CO: Technology controller actual value after filter / Tec_ctr act aftFlt
SERVO_S110-CAN
Can be changed: -
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Technology
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
- [%]
Description:
Displays the smoothed actual value after the filter (PT1) of the technology controller
1-348
D component in the actual value signal
D component in the fault signal
Calculated: -
Dynamic index: -
Units group: 9_1
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
60.000 [s]
Calculated: -
Dynamic index: -
Units group: 9_1
Scaling: PERCENT
Max
- [%]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 7958
Unit selection: p0595
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]
Access level: 2
Func. diagram: 7958
Unit selection: p0595