Siemens SINAMICS S110 List Manual page 324

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
14
External fault 2 (F07861) effective
15
External fault 3 (F07862) effective
Dependency:
Refer to: p2103, p2104, p2105, p2106, p2107, p2108, p2112, p2116, p2117
r2139.0...12
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the first status word of faults and alarms.
Bit field:
Bit
Signal name
00
Being acknowledged
01
Acknowledgment required
03
Fault present
05
Safety message present
06
Internal message 1 present
07
Alarm present
08
Internal message 2 present
11
Alarm class bit 0
12
Alarm class bit 1
Note:
Re bit 03, 05, 07:
These bits are set if at least one fault/alarm occurs. Data is entered into the fault/alarm buffer with delay. This is the
reason that the fault/alarm buffer should only be read if, after "fault present"/"alarm present" has occurred, a change
in the buffer was also detected (r0944, r9744, r2121).
Re bit 06, 08:
These status bits are used for internal diagnostic purposes only.
Re bit 11, 12:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes
only on certain automation systems with integrated SINAMICS functionality.
p2140[0...n]
Hysteresis speed 2 / n_hysteresis 2
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < = speed threshold value 2" (BO: r2197.1)
"|n_act| > speed threshold value 2" (BO: r2197.2)
Dependency:
Refer to: p2155, r2197
p2141[0...n]
Speed threshold 1 / n_thresh val 1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold value for the signal "f or n comparison value reached or exceeded" (BO: r2199.1).
Dependency:
Refer to: p2142, r2199
1-324
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
High
High
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
300.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No
-
No
-
Access level: 2
Func. diagram: 1530, 2548
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Low
-
Low
-
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
90.00 [rpm]
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
5.00 [rpm]