Parameter
List of parameters
p2194[0...n]
Torque threshold value 2 / M_thresh val 2
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [%]
Description:
Sets the torque threshold value for the message "Torque utilization < torque threshold value 2" (BO: r2199.11).
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: r0033, p2195, r2199
p2195[0...n]
Torque utilization switch-off delay / M_util t_off
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0.0 [ms]
Description:
Sets the switch-off delay time for the negated signal "run-up completed".
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: p2174, p2194
p2196[0...n]
Torque utilization scaling / M_util scal
SERVO_S110-CAN,
Can be changed: C2(1, 3), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0.00 [%]
Description:
Sets the scaling factor for torque utilization (r0033).
r2197.1...13
CO/BO: Status word monitoring 1 / ZSW monitor 1
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the first status word for monitoring functions.
Bit field:
Bit
Signal name
01
02
03
n_act >= 0
06
|n_act| > n_max
07
Speed setp - act val deviation in tolerance
t_off
13
|n_act| > n_max error
Note:
Re bit 01, 02:
The threshold value is set in p2155 and the hysteresis in p2140.
1-334
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
100.00 [%]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1000.0 [ms]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
1000.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
90.00 [%]
Access level: 2
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
800.0 [ms]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 1530, 2534
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
-
-
No
8011
No
8010
No
8011
No
-