The motor type of a catalog motor corresponds to the upper three digits of the code number or the following assign-
ment (if the particular motor type is listed):
Type/code number ranges
102 / 102xx, 112xx, 122xx
104 / 104xx, 114xx, 124xx
107 / 107xx, 117xx, 127xx
108 / 108xx, 118xx, 128xx
134 / 134xx, 144xx, 154xx
136 / 136xx, 146xx, 156xx
166 / 166xx, 176xx, 186xx
200 / 200xx, 210xx, 220xx
204 / 204xx, 214xx, 224xx
206 / 206xx, 216xx, 226xx
207 / 207xx, 217xx, 227xx
261 / 261xx, 262xx
283 / 283xx, 293xx
286 / 286xx, 296xx
403 / 403xx, 413xx
406 / 406xx, 416xx, 426xx
Notice:
If required, the list of motor codes/encoder codes can be found in the Appendix of the List Manual.
Note:
With p0300 = 10000, for a motor with DRIVE-CLiQ, the motor parameters are automatically downloaded, with
p0300 = 10001, the motor parameters of a second data set (if available).
If a motor type has not been selected (p0300 = 0), then the drive commissioning routine cannot be exited.
A motor type with a value above p0300 >= 100 describes motors for which a motor parameter list exists.
Motor types with a value below p0300 < 100 correspond to the selection of a third-party motor. When appropriately
selected, this means that the motor parameters are pre-assigned the settings for a third-party motor.
This also applies for parameters for a motor with DRIVE-CLiQ. In this case p0300 can only be set to p0300 = 10000
or 10001 (read motor parameters) or to the corresponding non-Siemens motor (first digit of the motor code number)
in order to be able to cancel the write protection.
p0301[0...n]
Motor code number selection / Mot code No. sel
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: FEM
Min
0
Description:
The parameter is used to select a motor from a motor parameter list.
When changing the code number (with the exception to the value 0), all of the motor parameters are pre-assigned
from the internally available parameter lists.
Dependency:
Code numbers can only be selected for motor types that correspond to the motor type selected in p0300. For 1PH2,
1PH4, 1PH7, 1PM4, 1PM6, 1FT6 motors, code numbers are also possible, whose fourth decimal position is greater
by a value of 1 or 2 than the matching motor type in p0300. For 1FE1 motors, the third decimal position can be
higher by a value of 1.
Refer to: p0300
Notice:
If required, the list of motor codes/encoder codes can be found in the Appendix of the List Manual.
Note:
The motor code number can only be changed if the matching catalog motor was first selected in p0300.
For a motor with DRIVE-CLiQ, p0301 cannot be changed. In this case, p0301 is automatically written to the code
number of the motor parameter read in (r0302) if p0300 is set to 10000.
When selecting a catalog motor (p0300 >= 100), drive commissioning can only be exited if a code number is
selected.
If, for direct drives, the motor code number (p0301) is changed, this does not automatically result in the angular
commutation offset being determined (p0431).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
65535
Parameter
List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-75