Siemens SINAMICS S110 List Manual page 572

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p9545
SI Motion SSM filter time (processor 1) / SI Mtn SSM filt P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the filter time for the SSM feedback signal to detect standstill.
Note:
The filter time is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9546
SI Motion SSM velocity limit (processor 1) / SI Mtn SSM v_limP1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill (n < nx).
When this limit value is undershot, the signal "SSM feedback signal active" (SGA n < n_x) is set.
For p9568 = 0, the value in p9546 is also applicable for the function "SAM".
Caution:
The following applies for p9506 = 3:
The "SAM" function is switched out if the selected threshold value is undershot.
Note:
F-DO: Failsafe Digital Output / SGA: Safety-related output
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring) / SGA n < nx: Safety-
related output n < nx
p9546
SI Motion SSM velocity limit (processor 1) / SI Mtn SSM v_limP1
SERVO_S110-CAN
Can be changed: C2(95)
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.00 [rpm]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill (n < nx).
When this limit value is undershot, the signal "SSM feedback signal active" (SGA n < n_x) is set.
For p9568 = 0, the value in p9546 is also applicable for the function "SAM".
Caution:
The following applies for p9506 = 3:
The "SAM" function is switched out if the selected threshold value is undershot.
Note:
F-DO: Failsafe Digital Output / SGA: Safety-related output
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring) / SGA n < nx: Safety-
related output n < nx
1-572
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
100.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000000.00 [mm/min]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000000.00 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 2860
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: 2860
Unit selection: -
Expert list: 1
Factory setting
20.00 [mm/min]
Access level: 3
Func. diagram: 2860
Unit selection: -
Expert list: 1
Factory setting
20.00 [rpm]

Hide quick links: