Siemens SINAMICS S110 List Manual page 287

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r2019[0...7]
Comm int error statistics / Comm err
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the receive errors at the commissioning interface (RS232).
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
p2020
Field bus interface baud rate / Field bus baud
CU_S110-DP
Can be changed: T
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
4
Description:
Sets the baud rate for the fieldbus interface USS.
Value:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
Note:
Fieldbus SS: Fieldbus interface
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
The parameter is set to the factory setting when the protocol is reselected.
p2021
Field bus interface address / Field bus address
CU_S110-DP
Can be changed: T
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
0
Description:
Displays or sets the address for the fieldbus interface USS.
The address can be set as follows:
1) Using the address switch on the Control Unit.
--> p2021 displays the address setting.
--> A change only becomes effective after a POWER ON.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
57600 baud
76800 baud
93750 baud
115200 baud
187500 baud
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
13
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
31
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
8
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-287