Siemens SINAMICS S110 List Manual page 202

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r1087
CO: Speed limit negative effective / n_limit neg eff
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Setpoints
Not for motor type: -
Min
- [rpm]
Description:
Displays the effective negative speed limit.
Dependency:
Refer to: p1082, p1086, p1088
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for the speed/velocity limit of the negative direction.
p1091[0...n]
Skip speed 1 / n_skip 1
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
0.000 [rpm]
Description:
Sets skip speed 1.
Dependency:
Refer to: p1092, p1093, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
Note:
The skip (suppression) speeds can be used to prevent the effects of mechanical resonance.
p1092[0...n]
Skip speed 2 / n_skip 2
SERVO_S110-CAN
Can be changed: U, T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
0.000 [rpm]
Description:
Sets skip speed 2.
Dependency:
Refer to: p1091, p1093, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
1-202
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 3050, 3095
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 3050
Unit selection: -
Expert list: 1
Factory setting
1086[0]
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents