Siemens SINAMICS S110 List Manual page 195

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p1042[0...n]
CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for the setpoint of the motorized potentiometer in the automatic mode.
Dependency:
Refer to: p1041
p1043[0...n]
BI: Motorized potentiometer accept setting value / MotP acc set val
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source to accept the setting value for the motorized potentiometer.
Dependency:
Refer to: p1044
Note:
The setting value (CI: p1044) becomes effective for a 0/1 edge of the setting command (BI: p1043).
p1044[0...n]
CI: Motorized potentiometer setting value / Mop set val
SERVO_S110-CAN
Can be changed: T
(Extended set),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
-
Description:
Sets the signal source for the setting value for the motorized potentiometer.
Dependency:
Refer to: p1043
Note:
The setting value (CI: p1044) becomes effective for a 0/1 edge of the setting command (BI: p1043).
r1045
CO: Mot. potentiometer speed setp. in front of ramp-fct. gen. / Mop n_set bef RFG
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
- [rpm]
Description:
Sets the effective setpoint in front of the internal motorized potentiometer ramp-function generator.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Parameter
List of parameters
Access level: 3
Func. diagram: 3020
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3020
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3020
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3020
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
1-195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents