Siemens SINAMICS S110 List Manual page 423

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p3041
MotId moment of inertia identified / M_inertia ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: REL
Min
0.000000 [kgm²]
Description:
Motor moment of inertia determined by the motor data identification.
This motor moment of inertia can be changed after the identification and accepted in p0341 with p1910/p1960 = -3.
Dependency:
Refer to: p0341, p1960, r1969
p3042
MotId load moment of inertia identified / Load mom ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
0.00000 [kgm²]
Description:
Load moment of inertia determined by the motor data identification.
This load moment of inertia can be changed after the identification and accepted in p1498 with p1910/p1960 = -3.
Dependency:
Refer to: p0342, p1498, p1960, r1969
Note:
For p1910/p1960 = -3, p0342 is set to 1 (ratio between the total and motor).
p3049[0...n]
MotId Speed at start of field weakening identified / ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
0.00000 [rpm]
Description:
Speed at the start of field weakening determined by the motor data identification.
This start speed can be changed after the identification and accepted in p0348 with p1910/p1960 = -3.
Dependency:
Refer to: p0348, p1910, p1960
p3050[0...n]
MotorId stator resistance identified / R_stator ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
0.00000 [ohm]
Description:
Stator resistance determined by the motor data identification.
This stator resistance can be changed after the identification and accepted in p0350 with p1910/p1960 = -3.
Dependency:
Refer to: p0350, p1910, r1912
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: CALC_MOD_ALL
Dynamic index: -
Units group: 25_1
Scaling: -
Max
100000.000000 [kgm²]
Calculated: CALC_MOD_ALL
Dynamic index: -
Units group: 25_1
Scaling: -
Max
100000.00000 [kgm²]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
210000.00000 [rpm]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: 16_1
Scaling: -
Max
2000.00000 [ohm]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
0.000000 [kgm²]
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
0.00000 [kgm²]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00000 [rpm]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [ohm]
1-423

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents