Siemens SINAMICS S110 List Manual page 376

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Note:
When calculating the torque pre-control value (r2654), the time derivation of the speed pre-control value is multi-
plied by 2 PI * p2567.
For reasons associated with the compatibility to earlier firmware versions, the factory setting for p2567 = 1 kgm^2/2
PI. This means that CO: r2564 remains as standard the derivation over time of the speed pre-control value and is
referred, as before, to a moment of inertia of 1 kgm^2/2 PI. For torque pre-control, the moment of inertia can now be
directly entered into p2567 (instead of subsequently evaluating the pre-control value.
p2568
BI: EPOS STOP cam activation / STOP cam act
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source to activate the function "STOP cam".
BI: p2568 = 1 signal
--> The evaluation of the STOP cam minus (BI: p2569) and STOP cam plus (BI: p2570) is active.
Dependency:
Refer to: p2569, p2570
Note:
The traversing range can also be limited using software limit switches.
p2569
BI: EPOS STOP cam minus / STOP cam minus
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the STOP cam in the negative direction of travel.
Recommend.:
Set the OFF3 ramp-down time (p1135), so that the axis, after reaching the STOP cam at the maximum velocity,
does not move through a higher braking travel than is actually available.
Sets message 07491 as alarm (A07491):
Set the maximum deceleration (p2573), so that the axis, after reaching the STOP cam at the maximum velocity,
does not move through a higher braking travel than is actually available.
Dependency:
Refer to: p1135, p2568, p2570, p2573, r2684
Refer to: F07491
Caution:
The STOP cams are low active.
Sets message 07491 as fault (F07491):
For a 0 signal, the axis is stopped with the OFF3 ramp-down time (p1135), status signal r2684.13 is set to 1, saved
and the appropriate fault is output. After the fault has been acknowledged, only motion moving away from the STOP
cam is permitted.
For a 0/1 signal and valid travel direction, when the stop cam is exited, this is detected and the status signal
r2684.13 is set to 0.
Sets message 07491 as alarm (A07491):
For a 0 signal, the axis is stopped with the maximum deceleration (p2573), status signal r2684.13 is set to 1, saved
and the appropriate alarm is output. Only motion away from the STOP cam is permitted.
For a 0/1 signal and valid travel direction, when the stop cam is exited, this is detected and the status signal
r2684.13 is set to 0 and the alarm is deleted.
1-376
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3630
Unit selection: -
Expert list: 1
Factory setting
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents