Parameter
List of parameters
Note:
1 signal: Brake open.
When braking with 1 feedback signal, the inverted feedback signal is connected to the BICO input for the second
feedback signal (p1222).
p1224[0...3]
BI: Close motor holding brake at standstill / Brk close standst
SERVO_S110-CAN
Can be changed: T
(Extended brk),
Data type: Unsigned32 / Binary
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Sets the signal source for close brake at standstill.
Dependency:
Refer to: p1275
Note:
[0]: Signal, close brake at standstill, inversion via p1275.2
[1]: Signal, close brake at standstill, inversion via p1275.3
[2]: Signal, close brake at standstill
[3]: Signal, close brake at standstill
These four signals form an OR logic operation.
p1225
CI: Standstill detection, threshold value / Standstill thresh
SERVO_S110-CAN
Can be changed: T
(Extended brk),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Sets the signal source "threshold value" for the standstill identification.
Dependency:
Refer to: p1226, p1228, r1229
p1226[0...n]
Threshold for zero speed detection / n_standst n_thresh
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Functions
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold for the standstill identification.
Acts on the actual value and setpoint monitoring.
When braking with OFF1 or OFF3, when the threshold is undershot, standstill is identified.
The following applies when the brake control is activated:
When the threshold is undershot, the brake control is started and the system waits for the brake closing time in
p1217. The pulses are then suppressed.
if the brake control is not activated, the following applies:
When the threshold is undershot, the pulses are suppressed and the drive coasts down.
Dependency:
Refer to: p1215, p1216, p1217, p1227
Notice:
For reasons relating to the compatibility to earlier firmware versions, a parameter value of zero in indices 1 to 31 is
overwritten with the parameter value in index 0 when the Control Unit boots.
1-222
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 2704
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2704
Unit selection: -
Expert list: 1
Factory setting
63[0]
Access level: 2
Func. diagram: 2701, 2704
Unit selection: p0505
Expert list: 1
Factory setting
20.00 [rpm]