p3103
RTC synchronization source / RTC sync_source
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the synchronization source/technique.
Value:
0:
1:
2:
3:
p3104
BI: RTC real time synchronization PING / RTC PING
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the PING event to set the UTC time.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
r3108[0...1]
RTC last synchronization deviation / RTC sync_dev
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the last synchronization deviation that was determined.
r3108[0]: Milliseconds
r3108[1]: Days
p3109
RTC real time synchronization, tolerance window / RTC sync tol
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the tolerance window for time synchronization.
When this tolerance window is exceeded, an appropriate alarm is output.
Dependency:
Refer to: A01099
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
PROFIBUS
PROFINET
PPI
PROFINET PTP
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100 [ms]
1-427