08
System time synchronized
12
Slave sign-of-life bit 0
13
Slave sign-of-life bit 1
14
Slave sign-of-life bit 2
15
Slave sign-of-life bit 3
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word of the sequence control.
Bit field:
Bit
Signal name
00
Rdy for switch on
01
Ready
02
Operation enabled
03
Jog active
04
No coasting active
05
No Quick Stop active
06
Switching on inhibited active
07
Drive ready
08
Controller enable
09
Control request
11
Pulses enabled
12
Open holding brake
13
Command close holding brake
14
Pulse enable from the brake control
15
Setpoint enable from the brake control
Note:
Re bits 00, 01, 02, 04, 05, 06, 09:
For PROFIdrive, these signals are used for status word 1.
Re bit 13:
When the "Safe Brake Control" (SBC) is activated and selected, the brake is no longer controlled using this signal.
Re bit 14, 15:
These signals are only of significance when the "extended brake control" function module is activated (r0108.14 =
1).
p0918
PROFIBUS address / PB address
CU_S110-DP
Can be changed: T
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
1
Description:
Displays or sets the PROFIBUS address for PROFIBUS interface on the Control Unit.
The address can be set as follows:
1) Using the DIP switch on the Control Unit.
--> p0918 can then only be read and displays the selected address.
--> A change only becomes effective after a POWER ON.
2) Using p0918
--> Only if all of the DIP switches are set to ON or OFF.
--> The address is saved in a non-volatile fashion using the function "copy from RAM to ROM".
--> A change only becomes effective after a POWER ON.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
OFF2 inactive
OFF3 inactive
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
126
Parameter
List of parameters
No
-
No
-
No
-
No
-
No
-
Access level: 2
Func. diagram: 1530, 2503
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
OFF2 active
-
OFF3 active
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 2
Func. diagram: 1520, 2410
Unit selection: -
Expert list: 1
Factory setting
126