p0680[0...7]
Central measuring probe, input terminal / Cen meas inp
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the digital input used for the function "central measuring probe evaluation".
p0680[0]: Digital input, measuring probe 1
p0680[1]: Digital input, measuring probe 2
...
p0680[7]: Digital input, measuring probe 8
Value:
0:
1:
2:
3:
7:
Dependency:
Refer to: p0728
Note:
DI/DO: Bidirectional Digital Input/Output
Prerequisite: The DI/DO must be set as input (p0728.x = 0).
If a parameter change is rejected, a check should be performed as to whether the input terminal is already being
used in p0488, p0489, p0493, p0494, p0495, p0580, p2517 or p2518.
p0681
BI: Central measuring probe, synchronizing signal signal source /
Cen meas sync_sig
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for the synchronizing signal (SYN) of the function "central measuring probe evaluation".
The signal is used to synchronize the common system time between the master and slave.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0682
CI: Central measuring probe, control word signal source / Cen meas STW S_src
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Integer16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Sets the signal source for the control word of the function "central measuring probe evaluation".
p0684
Central measuring probe evaluation technique / Cen meas eval_tech
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the evaluation technique for the "central measuring probe evaluation" function.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No measuring probe
DI/DO 9 (X132.2)
DI/DO 10 (X132.3)
DI/DO 11 (X132.4)
DI/DO 8 (X132.1)
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-141