Siemens SINAMICS S110 List Manual page 313

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p2098[0...1]
Inverter connector-binector converter binector output / Con/bin outp inv
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Communications
Not for motor type: -
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of CI: p2099[0] are influenced.
Using p2098[1], the signals of CI: p2099[1] are influenced.
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
Dependency:
Refer to: r2094, r2095, p2099
p2099[0...1]
CI: Connector-binector converter signal source / Con/bin S_src
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Integer16
SERVO_S110-PN
P-Group: Communications
Not for motor type: -
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on (intercon-
nection).
Dependency:
Refer to: r2094, r2095
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p2099[0...1] together with r2094.0...15 and r2095.0...15 forms two connector-binector converters:
Connector input p2099[0] to binector output in r2094.0...15
Connector input p2099[1] to binector output in r2095.0...15
p2100[0...19]
Setting the fault number for fault response / F_no F response
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0
Description:
Selects the faults for which the fault response should be changed
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Parameter
List of parameters
Access level: 3
Func. diagram: 2468
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
FP
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Not inverted
-
Access level: 3
Func. diagram: 2468
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 1750, 8075
Unit selection: -
Expert list: 1
Factory setting
0
1-313