Siemens SINAMICS S110 List Manual page 142

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Value:
0:
1:
Note:
During measurement without a handshake, the probe may have a higher evaluation frequency.
The setting "Measurement without handshake" must be supported by the higher-level control. This setting cannot
be used for SIMOTION D with integrated SINAMICS or with CX32.
r0685
Central measuring probe, control word display / Cen meas STW disp
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the control word for the function "central measuring probe evaluation".
Bit field:
Bit
Signal name
00
Falling edge, measuring probe 1
01
Falling edge, measuring probe 2
02
Falling edge, measuring probe 3
03
Falling edge, measuring probe 4
04
Falling edge, measuring probe 5
05
Falling edge, measuring probe 6
06
Falling edge, measuring probe 7
07
Falling edge, measuring probe 8
08
Rising edge, measuring probe 1
09
Rising edge, measuring probe 2
10
Rising edge, measuring probe 3
11
Rising edge, measuring probe 4
12
Rising edge, measuring probe 5
13
Rising edge, measuring probe 6
14
Rising edge, measuring probe 7
15
Rising edge, measuring probe 8
r0686[0...7]
CO: Central measuring probe, measuring time rising edge / CenMeas t_meas 0/1
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the measuring time for a rising edge at the digital input for the "central measuring probe evaluation" func-
tion.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0686[0]: Measuring time, rising edge measuring probe 1
r0686[1]: Measuring time, rising edge measuring probe 2
r0686[2]: Measuring time, rising edge measuring probe 3
r0686[3]: Measuring time, rising edge measuring probe 4
r0686[4]: Measuring time, rising edge measuring probe 5
r0686[5]: Measuring time, rising edge measuring probe 6
r0686[6]: Measuring time, rising edge measuring probe 7
r0686[7]: Measuring time, rising edge measuring probe 8
1-142
Measurement with handshake
Measurement without handshake
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading