p0335[0...n]
Motor cooling type / Motor cooling type
SERVO_S110-CAN,
Can be changed: C2(1, 3), T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL, FEM
Min
0
Description:
Sets the motor cooling system used.
Value:
0:
1:
2:
4:
5:
6:
128:
Dependency:
For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The parameter influences the thermal 3-mass motor model.
1LA1 and 1LA8 motors are characterized by the fact that they have an internal rotor fan. This "internal cooling" lies
within the motor frame and is not visible. Air is not directly exchanged with the motor ambient air. For 1PQ8 motors,
p0335 should be set to 5 as these motors are force-ventilated motors.
1LA7 motors, frame size 56 are operated without fan.
r0336[0...n]
Actual rated motor frequency / Mot f_rated act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
- [Hz]
Description:
Displays the rated frequency of the motor.
For p0310 > 0, this value is displayed.
Dependency:
Refer to: p0311, p0314
Note:
For p0310 = 0 or for synchronous motors, the rated motor frequency r0336 is calculated from the rated speed and
the pole pair number.
For p0310 > 0, this value is displayed (not for synchronous motors).
r0337[0...n]
Rated motor EMF / Mot EMF_rated
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: REL
Min
- [Vrms]
Description:
Displays the rated EMF of the motor.
Note:
EMF: Electromagnetic force
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Non-ventilated
Forced cooling
Liquid cooling
Non-ventilated and internal fan
Forced cooling and internal fan
Liquid cooling and internal fan
No fan
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
128
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
- [Hz]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
- [Vrms]
Parameter
List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
1-85