Device type:
r0964[1] = 5400 --> SINAMICS S110 CU305 DP
r0964[1] = 5401 --> SINAMICS S110 CU305 PN
r0964[1] = 5402 --> SINAMICS S110 CU305 CAN
r0965
PROFIdrive profile number / PD profile number
CU_S110-DP,
Can be changed: -
CU_S110-PN
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the PROFIdrive profile number and profile version.
Constant value = 0329 hex.
Byte 1: Profile number = 03 hex = PROFIdrive profile
Byte 2: Profile version = 29 hex = Version 4.1
Note:
When the parameter is read via PROFIdrive, the Octet String 2 data type applies.
p0969
System runtime relative / t_System relative
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0 [ms]
Description:
Displays the system runtime in ms since the last POWER ON.
Note:
The value in p0969 can only be reset to 0.
The value overflows after approx. 49 days.
When the parameter is read via PROFIdrive, the TimeDifference data type applies.
p0970
Reset drive parameters / Drive par reset
SERVO_S110-CAN,
Can be changed: C2(30)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Factory settings
Not for motor type: -
Min
0
Description:
The parameter is used to initiate the reset of the parameters of an individual drive unit.
Parameters p0100, p0205 (only for VECTOR) and the parameters of the basic drive commissioning (p0009) are not
reset (p0107, p0108, p0111, p0112, p0115, p0121, p0130, p0131, p0140, p0141, p0142, p0170, p0186 ... p0189).
These can only be reset using the factory setting of the complete drive unit (p0976).
Value:
0:
1:
5:
100:
Dependency:
Refer to: F01659
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Parameter reset has been completed if p0970 and p0010 have been set to 0.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Inactive
Start a parameter reset
Starts a safety parameter reset
Start a BICO interconnection reset
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4294967295 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
100
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 1750, 8060
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents