Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1529[0...n]
CI: Torque limit lower/regenerative scaling / M_max low/gen scal
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the lower torque limit or the regenerative torque limit in p1523.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1530[0...n]
Power limit motoring / P_max mot
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.00 [kW]
Description:
Sets the power limit when motoring.
Dependency:
Refer to: p0500, p1531
p1531[0...n]
Power limit regenerative / P_max gen
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-100000.00 [kW]
Description:
Sets the regenerative power limit.
Dependency:
Refer to: p0500, p1530
p1532[0...n]
CO: Torque limit offset / M_max offset
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
-100000.00 [Nm]
Description:
Sets the torque offset for the torque limit.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 14_5
Scaling: -
Max
100000.00 [kW]
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 14_5
Scaling: -
Max
-0.01 [kW]
Calculated: -
Dynamic index: DDS, p0180
Units group: 7_1
Scaling: p2003
Max
100000.00 [Nm]
Parameter
List of parameters
Access level: 3
Func. diagram: 1610, 3617,
5620, 5630
Unit selection: -
Expert list: 1
Factory setting
1525[0]
Access level: 2
Func. diagram: 5640
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [kW]
Access level: 2
Func. diagram: 5640
Unit selection: p0505
Expert list: 1
Factory setting
-0.01 [kW]
Access level: 3
Func. diagram: 5620, 5630,
5650, 7010, 8012
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]
1-255