Siemens SINAMICS S110 List Manual page 330

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r2169
CO: Actual speed smoothed signals / n_act smth message
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
- [rpm]
Description:
Displays the smoothed actual speed for messages/signals.
Dependency:
Refer to: p2153
p2174[0...n]
Torque threshold value 1 / M_thresh val 1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the torque threshold value for the signal "Torque setpoint < torque threshold value 1" (BO: r2198.10).
Dependency:
Refer to: p2195, r2198
p2175[0...n]
Motor locked speed threshold / Mot lock n_thresh
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold for the message "Motor locked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2177, r2198
p2177[0...n]
Motor locked delay time / Mot lock t_del
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.000 [s]
Description:
Sets the delay time for the message "Motor locked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2175, r2198
p2181[0...n]
Load monitoring response / Load monit resp
SERVO_S110-CAN
Can be changed: U, T
(Ext msg),
Data type: Integer16
SERVO_S110-DP
P-Group: Messages
(Ext msg),
Not for motor type: -
SERVO_S110-PN
(Ext msg)
Min
0
Description:
Sets the response when evaluating the load monitoring.
1-330
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
65.000 [s]
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
6
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 1750, 8010,
8012, 8013
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: 8012
Unit selection: p0505
Expert list: 1
Factory setting
5.13 [Nm]
Access level: 3
Func. diagram: 8012
Unit selection: p0505
Expert list: 1
Factory setting
120.00 [rpm]
Access level: 2
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
1.000 [s]
Access level: 3
Func. diagram: 8013
Unit selection: -
Expert list: 1
Factory setting
0

Hide quick links: