r1915
Stator inductance identified / L_stator ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified stator inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951
r1925
Threshold voltage identified / U_threshold ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [Vrms]
Description:
Displays the identified threshold voltage of the power unit.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951
r1927
Rotor resistance identified / R_rotor ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [ohm]
Description:
Displays the identified rotor resistance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1932, r1933, r1934, r1935, r1936, r1950, r1951
r1932[0...19]
d inductance identified / Ld ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified (differential) d-inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1933, r1934, r1935, r1936, r1950, r1951
Note:
The Ld characteristic consists of the value pairs from p1932 and p1933 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
r1933[0...19]
d inductance identification current / Ld I_ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [Arms]
Description:
Displays the identification current of the d inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1932, r1934, r1935, r1936, r1950, r1951
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [mH]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Vrms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ohm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [mH]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Arms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ohm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Arms]