Siemens SINAMICS S110 List Manual page 61

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r0146[0...n]
Encoder interface active/inactive / Enc_intf act/inact
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Displays the "active" or "inactive" state of an encoder interface (Sensor Module).
Value:
0:
1:
Dependency:
Refer to: p0145, p0480, p0897
r0147[0...n]
Sensor Module EEPROM data version / SM EEPROM version
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the version of the EEPROM data of the Sensor Module.
Dependency:
Refer to: r0127
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0148[0...n]
Sensor Module firmware version / SM FW version
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the firmware version of the Sensor Module.
Dependency:
Refer to: r0018, r0128, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0162
Reactor module component number / Reactor comp_no
SERVO_S110-CAN,
Can be changed: C1(4)
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Terminals
Not for motor type: -
Min
0
Description:
Sets the component number for the reactor module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a filter module.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Component inactive
Component active
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
199
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents