Siemens SINAMICS S110 List Manual page 430

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
r3123[0...63]
Diagnostic attribute alarm / Diag_attr alarm
All objects
Can be changed: -
Data type: Unsigned32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the diagnostic attribute of the alarm which has occurred.
Bit field:
Bit
Signal name
00
Hardware replacement recommended
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2134, r2145, r2146, r3121
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
r3131
CO: Current flt value / Current flt value
All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the fault value of the oldest active fault.
Dependency:
Refer to: r2131, r3132
r3132
CO: Actual component number / Act comp_no.
All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the component number of the oldest fault that is still active.
Dependency:
Refer to: r2131, r3131
p3135
Suppress active fault / Supp act flt
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the suppression of r2139.3 "Fault present" for certain fault responses.
Bit field:
Bit
Signal name
08
Suppression of fault response ENCODER
10
Suppression of fault response NONE
Dependency:
Refer to: p0491, r2139
Note:
Depending on the suppression of a fault reaction in this parameter, r2139.1 "Acknowledgement required" is set
when at least one fault occurs.
Re bit 08:
The suppression is only effective if p0491 = 1.
1-430
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 8065
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
FP
OFF
-
OFF
-