p0819[0...2]
Copy Drive Data Set DDS / Copy DDS
SERVO_S110-CAN,
Can be changed: C2(15)
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Copies one Drive Data Set (DDS) into another.
Index:
[0] = Source Drive Data Set
[1] = Target Drive Data Set
[2] = Start copying procedure
Note:
Procedure:
1. In Index 0, enter which drive data set is to be copied.
2. In Index 1, enter the drive data set data that is to be copied into.
3. Start copying: Set index 2 from 0 to 1.
p0819[2] is automatically set to 0 when copying is completed.
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
SERVO_S110-CAN,
Can be changed: C2(15), T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 0 (DDS, bit 0).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0826[0...n]
Motor changeover, motor number / Mot_chng mot No.
SERVO_S110-CAN,
Can be changed: C2(3)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the freely-assignable motor number for the motor changeover.
Dependency:
Refer to: p0827
Caution:
When changing over motor data sets with the same motor number (e.g. star-delta changeover) and for a motor with
brake, the motor brake remains open during the changeover.
Note:
When the motor data sets are changed over, the following applies:
The same motor number signifies the same thermal model.
p0827[0...n]
Motor changeover status word bit number / Mot_chg ZSW bitNo.
SERVO_S110-CAN,
Can be changed: C2(3)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the bit number for every motor data set.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
31
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
15
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
15
Parameter
List of parameters
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8565, 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0