r0049[0...3]
Motor data set/encoder data set effective / MDS/EDS effective
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective Motor Data Set (MDS) and the effective Encoder Data Sets (EDS).
Index:
[0] = Motor Data Set MDS effective
[1] = Encoder 1 Encoder Data Set EDS effective
[2] = Encoder 2 Encoder Data Set EDS effective
[3] = Reserved
Dependency:
Refer to: p0186, p0187, p0188, r0838
Note:
Value 99 means the following: No encoder assigned (not configured).
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective Command Data Set (CDS).
Bit field:
Bit
Signal name
00
CDS eff., bit 0
01
CDS eff., bit 1
Dependency:
Refer to: p0810, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
1-44
MotID: Reluctance constant measurement end
MotID: Moment of inertia measurement, step 1
MotID: Moment of inertia measurement, step 2
MotID: Moment of inertia measurement, step 3
MotID: Moment of inertia measurement end
MotID: Magnetizing inductance measurement, step 1
MotID: Magnetizing inductance measurement, step 2
MotID: Magnetizing inductance measurement, step 3
MotID: Magnetizing inductance measurement evaluation
MotID: Magnetizing inductance measurement end
MotID: Saturation characteristic. step 1
MotID: Saturation characteristic. step 2
MotID: Saturation characteristic. step 3
MotID: Saturation characteristic evaluation 1
MotID: Saturation characteristic evaluation 2
MotID: Saturation characteristic end
MotID: Converter model, step 1
MotID: Converter model, step 2
MotID: Converter model, step 3
MotID: Converter model, step 4
PolID: Motion-based, step 1
PolID: Motion-based, step 2
PolID: Motion-based, step 3
PolID: Motion-based, step 4
PolID: Motion-based, step 5
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8560
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
OFF
-
OFF
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents