p0305[0...n]
Rated motor current / Mot I_rated
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0.00 [Arms]
Description:
Sets the rated motor current (rating plate).
Dependency:
Refer to: p0349
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Notice:
If p0305 is changed during quick commissioning (p0010 = 1), then the maximum current p0640 is pre-assigned
accordingly. This is not the case when commissioning the motor (p0010 = 3).
Note:
When the parameter value is entered the connection type of the motor (star-delta) must be taken into account.
p0307[0...n]
Rated motor power / Mot P_rated
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0.00 [kW]
Description:
Sets the rated motor power (rating plate).
Dependency:
IECdrives (p0100 = 0): Units kW
NEMA drives (p0100 = 1): Units hp
Refer to: p0100
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
p0308[0...n]
Rated motor power factor / Mot cos_phi_rated
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL
Min
0.000
Description:
Sets the rated motor power factor (cos phi, rating plate).
For a parameter value of 0.000, the power factor is internally calculated and displayed in r0332.
Dependency:
This parameter is only available for IEC motors (p0100 = 0).
Refer to: p0100, r0332
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
p0310[0...n]
Rated motor frequency / Mot f_rated
SERVO_S110-CAN,
Can be changed: C2(1, 3)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0.00 [Hz]
Description:
Sets the rated motor frequency (rating plate).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
10000.00 [Arms]
Calculated: -
Dynamic index: MDS, p0130
Units group: 14_6
Scaling: -
Max
100000.00 [kW]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
1.000
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
3000.00 [Hz]
Parameter
List of parameters
Access level: 1
Func. diagram: 6300
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 1
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
0.00 [kW]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Hz]
1-77