p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Functions
Not for motor type: REL
Min
0.00 [A/V]
Description:
Sets the proportional gain for the DC-link voltage controller (Vdc_min controller, Vdc_max controller).
Dependency:
Refer to: p1240, p1244, p1248
p1275
Motor holding brake control word / Brake STW
SERVO_S110-CAN
Can be changed: U, T
(Extended brk),
Data type: Unsigned32
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
-
Description:
Sets the control word for the motor holding brake.
Bit field:
Bit
Signal name
00
Inverting BI: 1219[0]
01
Inverting BI: 1219[1]
02
Inverting BI: 1224[0]
03
Inverting BI: 1224[1]
05
Brake with feedback
p1276
Motor holding brake, standstill detection, bypass / Brk standst bypass
SERVO_S110-CAN
Can be changed: U, T
(Extended brk),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
0.000 [s]
Description:
Sets the delay time for closing the brake at standstill.
After this time has expired, if the "close brake at standstill" or OFF1/OFF3 is present, the brake is closed and the
pulses are suppressed.
For p1276 = 300.000 s, the timer is de-activated - this means that the timer output is always zero.
p1277
Motor holding brake, braking threshold delay exceeded / Del thresh exceed.
SERVO_S110-CAN
Can be changed: U, T
(Extended brk),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Functions
(Extended brk),
Not for motor type: -
SERVO_S110-PN
(Extended brk)
Min
0.000 [s]
Description:
Sets the delay time for the signal "braking threshold exceeded" (BO: r1229.6).
Dependency:
Refer to: p1220, p1221, r1229
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: CALC_MOD_CON
Dynamic index: DDS, p0180
Units group: 19_1
Scaling: -
Max
10.00 [A/V]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
300.000 [s]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
300.000 [s]
Parameter
List of parameters
Access level: 3
Func. diagram: 5650
Unit selection: p0505
Expert list: 1
Factory setting
1.00 [A/V]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 bin
0 signal
FP
No
2707
No
2707
No
2704
No
2704
No
2711
Access level: 2
Func. diagram: 2704
Unit selection: -
Expert list: 1
Factory setting
300.000 [s]
Access level: 2
Func. diagram: 2707
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]